Skip to content

FSE(w)

  • Self-regulating heating cable for temperature maintenance
  • 100°C: maximum tolerance temperature with powered cable
  • Automatically varies power output as temperature changes
  • For industrial applications in explosion and fire zones
  • External temperature control not required

FSE(w)

Notes on operation:

  • Maximum tolerance temperature with powered and unpowered cable: 100°C
  • Minimum installation temperature: -40°C
  • Minimum operating temperature: -65°C
  • Power supply voltage: 220-277 V a.c.
  • W/m available: 17, 31, 45, 60

Examples of application:

  • Antifreeze function of products with design temperatures up to 100°C
  • Temperature maintenance of fluids in general, including highly corrosive ones
  • Installation in zones with explosion and fire hazards (ATEX)

Temperature classes:
17 e 31 W/m
T4 (135°C)
45 e 60 W/m
T3 (200°C)
Model Nominal dimensions (mm) Minimum bending radius Safe zone cable gland ATEX cable gland
FSE CT 12,7 x 5,95 35mm M25 M20
FSE CF 12,4 x 5,65 35mm M25 M25
FSE(w) CT 15,4 x 6,5 40mm M25 M25
FSE(w) CF 15,1 x 6,2 40mm M25 M25

FSE(w) CT

Version with metal mechanical protection sleeve and earthing braid with subsequent thermoplastic coating.

FSE(w) CF

Version with metal mechanical protection sleeve and earthing braid and subsequent fluoropolymer coating.

 

Maximum circuit length in metres depending on the size of the circuit breaker used and 230V ac power supply:

 

ModelStarting temperature6A 10A 16A 20A 25A
17FSE10°C4676120148-
0°C366298122148
'-20°C24426682102
'-40°C1628445668
31FSE10°C325282104110
0°C26426884106
'-20°C1628465670
'-40°C1218303848
45FSEw10°C2438627696
0°C2032506480
'-20°C1222344252
'-40°C814222834
60FSEw10°C2035526682
0°C1628445670
'-20°C1220324050
'-40°C814222834

With differential circuit breaker protection 30 mA curve C according to IEC60898

The FREEZSTOP EXTRA FSE is a self-regulating heating cable with semi-conductive matrix, an ideal solution for antifreeze systems and for maintaining water and fluid temperatures up to 100°C. Its inherent ability to self-limit its temperature to a value below the maximum allowed by the materials used in its construction allows it to be used without any need for thermostatic control. Installation is quick and easy as it can be cut, branched and terminated to size directly on site without the need for special equipment.

 

Temperature curve:

The graph shows the power rating supplied with a 230 V ac power supply and the cable installed on a suitably insulated metal pipe and dimensioned according to standards IEC 62395 and IEC 60079-30

Certifications

Request an Online Quote now

For more information on our products and areas of application, please do not hesitate to contact us, we will provide you with all the details you need.