HTM

  • Heating cable for freeze protection
  • 65°C: maximum tolerance temperature with powered cable
  • Automatically varies power output as temperature changes
  • For freeze protection in industrial and civil applications
  • Does not produce dangerous overheating or deterioration even when overlaid

HTM

Notes on operation:

  • Maximum tolerance temperature with powered cable 65°C and unpowered 85°C
  • Minimum installation temperature: -30°C
  • Minimum operating temperature: -60°C
  • Power supply voltage: 220-240 V ac
  • W/m available: 10, 15

Examples of application:

  • Freeze protection in industrial or civil applications with temperatures up to 65°C
  • Installation in zones with explosion and fire hazards (ATEX)

Temperature classes:
10 e 15 W/m
T6 (85°C)
Model Nominal dimensions (mm) Minimum bending radius Safe zone cable gland ATEX cable gland
HTM BT 9,0 x 5,8 25mm M25 M25
HTM BP 8,6 x 5,4 25mm M25 M25

HTM BT
Version with metal mechanical protection sleeve and earthing braid and subsequent thermoplastic coating.

HTM BP
Version with metal mechanical protection sleeve and earthing braid and subsequent fluoropolymer coating. For use in the presence of highly corrosive elements.

 

Maximum circuit length in metres depending on the size of the circuit breaker used and 230V ac power supply:

 

ModelStarting temperature10A 32A 40A
10HTM10°C130130130
0°C123123125
'-20°C110110110
'-40°C759090
15HTM10°C120150120
0°C109145109
'-20°C858585
'-40°C606565

With differential circuit breaker protection 30 mA curve C according to IEC60898

The HTM cable is a self-regulating semi-conductive matrix heating cable used for freeze protection in civil and industrial applications with temperatures up to 65°C. Its self-regulating characteristics make it very reliable and safe. It also does not produce overheating or burning, even when overlaid. HTM heating cable can be cut to length on site to the required length of the pipes, valves, pumps on which it is to be installed. It can be spliced and branched in parallel with extreme ease of design and installation and it is not necessary to know the exact layout of the system when ordering. No special equipment is required for its installation and it is secured to pipes with simple adhesive tape.

The kits include supply-side and terminal-side terminations and cable glands for connecting the heating cable directly into the power supply box.

 

Temperature curve:

The graph shows the power rating supplied with a 230 V ac power supply and the cable installed on a suitably insulated metal pipe and dimensioned according to standards IEC 62395 and IEC 60079-30.

Certifications